SXXI Fire resistance Shipboard power and control cable Application SXXI Fire resistance power and control cable is suitable for marine applications where circuit integrity is important in the event of a fire, including ship wiring.Unarmored fire resistant cable for fixed installation in ships where cable protection is needed.Power,control,alarm,emergency and critical systems.This cable can be installed and operated both indoors and outdoors.
SXXI Fire resistance Shipboard power and control cable Application
SXXI Fire resistance power and control cable is suitable for marine applications where circuit integrity is important in the event of a fire, including ship wiring.Unarmored fire resistant cable for fixed installation in ships where cable protection is needed.Power,control,alarm,emergency and critical systems.This cable can be installed and operated both indoors and outdoors.
SXXI Fire resistance Shipboard power and control cable Standards
| Design Guide | IEC 60092-350, 353 |
| Insulation Material | IEC 60092-351 |
| Sheath Material | IEC 60092-359 |
| Flammability |
IEC 60332-1 & IEC 60332-3 Category A |
| Fire Resistance | IEC 60331(750℃ or 1000℃) |
| Halogen Content | IEC 60754-1,2, 0.5%(Max.) |
| Smoke Emission | IEC 61034-1,2, 60%(Min.) |
SXXI Fire resistance Shipboard power and control cable Construction
| Classification | Code Letter | Construction Detail |
| Conductor |
|
Plain, Annealed, Stranded copper wire |
| Fire resisting layer | S | Mica/Glass Tape (MGT) |
| Insulation | Cross-linked Polyethylene (XLPE) as per IEC 60092-351 | |
| Inner Covering | X | Non |
| Armor | X | Non |
| Sheath | I | Halogen Free Thermoplastic compound (IEC 60092-359, SHF1)Sheath color Black |
SIOI SICI fire resistant Shipboard instrumentation cable
SFOI fire resistant shipboard instrumentation cable
TIOI TICI Armored shipboard telephone cable
TFOI ior c Individual and Collectively Screened instrumentation cable
TXXI i or c light weight shipboard communication cable
TXXI(i) light weight shipboard communication cable